• Eutectic plate TOP 370
  • INSULATED ROLL 1410 SEE OLIVO EUTECTIC PLATE TOP370
  • INSULATED ROLL 370 OLIVO EUTECTIC PLATE TOP370
  • EUTECTIC PLATES TROLLEYS OLIVO TOP370
  • Eutectic plate TOP 370
  • INSULATED ROLL 1410 SEE OLIVO EUTECTIC PLATE TOP370
  • INSULATED ROLL 370 OLIVO EUTECTIC PLATE TOP370
  • EUTECTIC PLATES TROLLEYS OLIVO TOP370

Plaque eutectique

Eutectic plate TOP 370

  • Length : 620 mm
  • Width : 420 mm
  • Thickness : 35 mm
  • Weight : 8.8 Kg
  • Existing temperature ranges :
    -12°C -17°C -21°C -26°C -3°C +21°C 0°C

Pour commander cette plaque eutectique, faites-en la demande dans la partie commentaire de votre demande de devis.

Vous avez une question ? Contactez-nous !

Installation of eutectic plates

The preparation of the eutectic plate varies according to the holding temperature required and the area of application.
A eutectic plate in its solid state is capable of absorbing energy: it heats up until it becomes completely liquid.
A eutectic plate in its liquid state is able to give up energy: it cools until it becomes completely solid.

Freezing cold eutectic plates

To solidify the eutectic plate :

The solidification of the eutectic solution must take place in an environment where the temperature is 5°C below the melting temperature of the plate. The duration of this phase change, from liquid to solid, depends on the energy input. Nevertheless, we recommend immobilisation in a cold chamber for 24 hours. However, the chamber must meet two fundamental criteria: it must be sufficiently powerful and ventilated to allow the free circulation of cold air around the faces of the eutectic plate. The use of a freezing rack optimises the preparation phase. An air gap of 2cm around the sides of the TOPs encourages convection and therefore the solidification of the plates.

=> How do I know if my eutectic sheet is ready for use?

A eutectic plate that is ready for use, i.e. 100% loaded, must be 100% solid if the outside temperature is higher than the temperature of the products being transported.

Without this sine qua none condition, we cannot guarantee that the temperature of the products transported will be maintained. To achieve this, it is necessary to comply with the eutectic plate preparation protocol: 24 hours of preparation in an enclosure where the temperature is at least 5°C below the melting temperature of the eutectic plate. The method of storing the plates during the loading phase is also decisive: 2cm of space between each plate to create corridors for the circulation of cold air.

Positioning the eutectic plate

To maximise cold diffusion in the isothermal enclosure, the eutectic plates should be placed in the appropriate positions.

As a reminder, cold spreads from top to bottom.

The isothermal containers are fitted with rotomoulded guides on which the sheets can be positioned directly or which allow a sheet-holder grid to slide over them.

To avoid damaging your fresh produce through direct contact with the cold source, we recommend that you leave 5 cm between the plate and the produce.

Containers and accessories compatible with this product

Containers and accessories compatible with this product

  • ROLL 220
    logoATP 1

    Ext. dim. : 600 x 800 x 1125 mm,

    Volume : 215 L,

    Cold sources : eutectic plate TOP 370 et SiberSnow ®,

    Logistics formats : Euronorm crate 600 x 400 et Half Euro-pallet 80 x 600

    View details
  • ROLL 220 CATERING
    logoATP 1

    Ext. dim. : 600 x 800 x 1130 mm,

    Volume : 215 L,

    Cold source : eutectic plate TOP 370,

    Logistics formats : Euronorm trays, Gastronorm trays et Half Euro-pallet 80 x 600

    View details
  • BAC 160
    logoATP 1

    Ext. dim. : 800 x 600 x 1050 mm,

    Volume : 159 L,

    Cold source : eutectic plate TOP 370,

    Logistics format : Half Euro-pallet 80 x 600

    View details
  • BAC 320
    logoATP 1

    Ext. dim. : 1200 x 800 x 965 mm,

    Volume : 327 L,

    Cold source : eutectic plate TOP 370,

    Logistics format : Euro-pallet 800 x 1200

    View details
  • ROLL 370
    logoATP 1

    Ext. dim. : 600 x 800 x 1670 mm,

    Volume : 364 L,

    Cold sources : eutectic plate TOP 370 et SiberSnow ®,

    Logistics formats : Euronorm crate 600 x 400 et Half Euro-pallet 80 x 600

    View details
  • ROLL 370 CATERING
    logoATP 1

    Ext. dim. : 600 x 800 x 1670 mm,

    Volume : 364 L,

    Cold source : eutectic plate TOP 370,

    Logistics formats : Euronorm trays, Gastronorm trays et Half Euro-pallet 80 x 600

    View details
  • ROLL 500
    logoATP 1

    Ext. dim. : 715 x 850 x 1700 mm,

    Volume : 500 L,

    Cold sources : eutectic plate TOP 370 et SiberSnow ®,

    Logistics format : Roll cage

    View details
  • ROLL 1100
    logoATP 1

    Ext. dim. : 1000 x 1200 x 1690 mm,

    Volume : 1092 L,

    Cold sources : eutectic plate TOP 370 et SiberSnow ®,

    Logistics format : ISO Pallet 1000 x 1200

    View details
  • ROLL 1300
    logoATP 1

    Ext. dim. : 1100 x 1100 x 1930 mm,

    Volume : 1285 L,

    Cold source : eutectic plate TOP 370,

    Logistics format : Asia pallet 1100 x 1100

    View details
  • ROLL 1410
    logoATP 1

    Ext. dim. : 1000 x 1200 x 2000 mm,

    Volume : 1420 L,

    Cold sources : eutectic plate TOP 370 et SiberSnow ®,

    Logistics format : ISO Pallet 1000 x 1200

    View details
See all products

Frequently asked questions about this product

  • Eutectic plates

    How does a eutectic plate work ?

    A eutectic plate is a device designed to store thermal energy, in the form of heat or cold, and then to release it gradually to maintain a specific temperature. It works on the thermodynamic principle of phase change, i.e. the transformation of a solution from liquid to solid state and vice versa.

    The eutectic plate absorbs the heat from outside the container while releasing a constant amount of cold. It is by passing from the solid to the liquid state, by the absorption-release phenomenon, that the eutectic plate maintains a constant temperature inside the insulated container.

  • Eutectic plates

    What are the parameters that guarantee the effectiveness of a eutectic plate ?

    How effective a eutectic plate is depends on several parameters, namely:

    • The capacity of the eutectic solution: the choice of solution is decisive. It must be selected taking account of the temperature range required to maintain products at the target temperature. Each temperature range [+2°C/+4°C, +2°C/+8°C, +15°C/+25°C, etc.] has a specific application;
    • The model of plate: the size and shape of the eutectic plate are two decisive factors as they are adapted to specific models of container;
    • The container: good thermal insulation prevents the transfer of heat, thereby maximising the performance de the eutectic plate (temperature maintenance time);
    • The method of preparation: the eutectic plate must be completely solid when it is used. It is as it liquefies that it releases the cold that keeps the products at the right temperature. For more details, you can download the protocol in the section Using eutectic plates;
  • Eutectic plates

    What is eutectic plate used for ?

    The eutectic plate is a device filled with an aqueous, saline solution and a food colouring. It absorbs heat input during transport and provides continuous cooling through the latent heat of fusion of the eutectic solution, which changes from a solid to a liquid state. Better suited to medium-sized logistics operations, the eutectic plate is a simple refrigeration system that maintains the temperature of products for 12 to 24 hours maximum.

Latent heat of fusion according to melting temperature in Joules

+21°C967 KJoules
0°C1990 KJoules
-3°C2051 KJoules
-12°C2146 KJoules
-17°C1945 KJoules
-21°C1896 KJoules
-26°C1892 KJoules